The SIKA France factory in Gournay-en-Bray, subsidiary of the Swiss group SIKA AG, mainly manufactures additives for concrete and sealing products. These products are used in the building sector. Their production generates liquid waste which, after treatment, can still exceed the authorised limits for waste in municipal plants. The main value involved was the COD (chemical oxygen demand).
The existing evaporator/concentrators reaching the end of their service life, SIKA France decided to replace them with a last generation H2O evaporator including the latest technological developments.
After visiting the H2O stand at the Pollutec trade fair, SIKA France explained its requirements.
Manufacturing at the SIKA site in Gournay-en-Bray is carried out in tanks to which different reagents are added. To be able to move from one production process to the next, the tanks must be cleaned and rinsed with water. This rinse water is then stored in large tanks before being treated. It contains various pollutants such as hydrocarbons, salts and surfactants.
Treatment is currently carried out by evaporation and concentration using equipment dating from 2001 and the distillate is stored before being discharged to the municipal biological treatment plant. In accordance with the agreement entered into with the Gournay-en-Bray treatment plant, the wastewater is periodically inspected and analysed. The municipal plant accepts effluents in which the level of pollutants does not exceed a certain limit. As a last resort, non-compliant distillate must be eliminated in an authorised treatment plant, a very costly operation.
The search for a solution to replace the ageing evaporators involved several criteria:
The Sika project team has drawn up a register of the loads, defining the quality of distillate necessary for recycling, whilst not ruling out the possibility of discharge into the municipal treatment plant. In addition, easy automated operation, as well as maintenance requiring few resources, were essential criteria when choosing a supplier.
A VACUDEST 4,500 Clearcat evaporator, which can treat up to 15 m³/day with a concentration factor of 20, or 5% concentrate, meets this demand. Sika adopted this vacuum evaporation solution and decided to embark on the path towards zero liquid discharge and recycling of distillates. This means that Sika will no longer discharge water into the municipal treatment plant and will eventually be liberated from the constraints of wastewater control.
Vacutouch machine control panel. Optimum availability and easy operation of the system.
After two years in operation, the evaporator is producing some highly satisfactory results. In fact, Mr Montier, Head of Environment and Energy affirmed,
“Installation was very quick and the training comprehensive. We have been able to recycle the distillate as its quality allowed it. The H2O after-sales service is competent, attentive and responsive. They called us back within the hour or within 24 hours at most. An H2O technician needs calling out at least twice a year to ensure that the machine is working correctly.
In 2 years, we have only produced 160 tonnes of concentrate in a treatment capacity of 3,500 tonnes. This means that the return on investment will be less than 2 and a half years.”
Comparison with the naked eye of the distillate from a traditional vacuum evaporator with that from a VACUDEST with the Clearcat option shows that the integrated Clearcat oil separator represents true progress in terms of the quality of the treated wastewater.
Sustainable
From 100 percent wastewater, 98 percent clean distillate is produced, which can be reused in your processes: You realise a wastewater-free production and thus make a valuable contribution to the protection of our environment.
Reliable
Our innovative technologies enable safe compliance with limit values. The treated water impresses with excellent quality that you can always rely on.
Economical
Our high-quality systems require hardly any manpower, save operating resources, and reduce disposal costs enormously. Therefore, our systems often pay for themselves in less than 2 years. After that, you save up to 10 million euros in 10 years.
In the end, SIKA confirms that the VACUDEST Clearcat was the right choice. From now on, the H2O after-sales service will take over to guarantee availability of the machine, to answer questions, carry out important maintenance and suggest improvements.
This installation was financed by the Seine-Normandy Water Board in the form of a subsidy of 40%.
You have questions on our VACUDEST systems?
Kindly contact us!
Your contact is:
Thomas Dotterweich
Senior Sales Engineer
+49 7627 9239-306
thomasm.dotterweich@h2o-de.com
You need consumables, spare parts or a maintenance date?
We will be pleased to assist you!
Your contact is:
Carles Fité
Technical Customer Support
+49 7627 9239-888
carles.fite@h2o-de.com
You want to be part of our team and create the wastewater-free future with us?
We will tell you how!
Your contact is:
Bettina Böhringer
Human Resources
+49 7627 9239-201
career@h2o-de.com